Based on this very useful web page http://web.archive.org/web/20121228004700/http://users.wowway.com:80/~captainkirk/computers/SolarisILOMALOMCheatSheet.htm
which is unfortunately offline now… so here for reference.

Solaris ILOM / ALOM Cheat Sheet

ILOM ALOM CMT Command Comparison

ALOM:       ILOM:
setdate     set /SP/clock datetime=value
                value format: MMDDhhmmYYYY

setdefaults set /SP reset_to_defaults=all
                -> reset /SP This resets the SP

setkeyswitch    set /SYS keyswitch_state=value
                value= normal, diag, stby, locked

setsc       set target property=value
setupsc     No equivalent in ILOM
setlocator  set /SYS/LOCATE value= Fast_Blink or off
setfru -c data  set /SYS customer_frudata=data
showplatform    show /HOST
showplatform    show /SYS ( to view Serial Number )
showfru     No equivalent in ILOM
showusers -g #  show /SP/users
showhost    show /HOST
showkeyswitch   show /SYS keyswitch_state

showsc param    show target property
VIEW DIAG LEVEL show /HOST/diag

setsc diag_level set /HOST/diag trigger=All-resets
                     none, normal, User-reset, Power-on-reset, Error-reset

showdate    show /SP/clock datetime

showlogs    show /SP/logs/event/list
showlogs    show /SP/faultmgmt
            set /SP/logs/event clear=true

showenvironment show -o table -level all /SYS
shownetwork show /SP/network
showlocator show /SYS/LOCATE
password    set /SP/users/<username> password
restartssh  set /SP/services/ssh restart_sshd_action=true
usershow    show /SP/users
useradd user    create /SP/users/<username>

Create "admin"  create /SP/users/admin
            set /SP/users/admin role=Administrator
            set /SP/users/admin cli_mode=alom

userdel user    delete /SP/users/<username>
userdel -y  delete -script /SP/users/<username>
userpassword    set /SP/users/<username> password
userperm user   set /SP/users/<username> role=permissions
consolehistory  SEE RENE FOR MORE INFO ;)
console -f  start -force /SP/console
break -c    set /HOST send_break_action=break
break -D    set /HOST send_break_action=dumpcore

bootmode    set /HOST/bootmode property=value
                state=value "reset_nvram or normal"
                script="setenv auto-boot? false"

flashupdate -s  load -source tftp://ipaddr/pathname
reset -c    reset /SYS
reset -y -c reset -script /SYS
powercycle  stop /SYS
powercycle -y   stop -script /SYS
powercycle -f   stop -force /SYS
        start -force /SYS
poweroff    stop /SYS
poweroff -y stop -script /SYS
poweroff -f stop -force /SYS
poweron     start /SYS
clearfault uuid set /SYS/component clear_fault_action=true
removefru -y    set /SYS/PS0 prepare_to_remove_action=true
enablecomponent set /SYS/component component_state=enabled
disablecomp set /SYS/component component_state=disabled
clearasrdb  No equivalent in ILOM
resetsc     reset /SP
resetsc -y  reset -script /SP
userclimode set /SP/users/<username> cli_mode=default or alom
logout      exit

DISPLAYING DIMM INFORMATION:

-> show /SYS/MB/CMP0/BR0/CH0/D#

    Targets:
        SEEPROM
        SERVICE
        PRSNT
        T_AMB

    Properties:
        type = DIMM
        component_state = Enabled
        fru_name = 4096MB DDR2 SDRAM FB-DIMM 333 (PC2 2600)
        fru_description = FBDIMM 4096 Mbyte
        fru_manufacturer = Samsung
        fru_version = FFFFFF
        fru_part_number = 501-7954-01 Rev 05
        fru_serial_number = 00CE01074627037EA3
        fault_state = OK
        clear_fault_action = (none)

Setting up Network Managment Port ILOM:

-> set pendingipaddress=<ip_address>
-> set pendingipdiscovery=static
-> set pendingipnetmask=255.255.255.0
-> set pendingipgateway=<ip_address>
-> set commitpending=true

Setting up Network Managment Port ALOM:

sc> setsc if_network true
sc> setsc if_connection "telnet or ssh"
sc> setsc netsc_dhcp false
sc> setsc netsc_ipaddr <ip_address>
sc> setsc netsc_ipnetmask <netmask>
sc> setsc netsc_ipgateway <ip_address>
sc> setsc netsc_commit

ALOM CMT Variable Comparison

ALOM:       ILOM:
diag_level  /HOST/diag level
diag_mode   /HOST/diag mode
diag_trigger    /HOST/diag trigger
diag_verbosity  /HOST/diag verbosity
if_connection   /SP/services/ssh state
if_emailalerts  /SP/clients/smtp state
if_network  /SP/network state
if_snmp     /SP/services/snmp
mgt_mailalert   /SP/alertmgmt/rules
mgt_mailhost    /SP/clients/smtp address
mgt_snmptraps   /SP/sevices/snmp v1|v2c|v3
mgt_traphost    /SP/alertmgmt/rules
        /SP/services/snmp port
netsc_dhcp  /SP/network pendingipdiscovery
netsc_commit    /SP/network commitpending=true
netsc_enetaddr  /SP/network macaddress
netsc_ipaddr    /SP/network pendingipaddress
netsc_ipgateway /SP/network pendingipgateway
netsc_ipnetmask /SP/network pendingipnetmask
sc_backupuserdata   /SP BACKUP_USER_DATA
sc_customerinfo /SP system_identifier
sc_escapechars  /SP/console escapechars
sc_powerondelay /SP/policy HOST_POWER_ON_DELAY

sc_powerstatememory /SP/policy HOST_LAST_POWER_STATE
                    States= enabled or disabled

ser_baudrate    /SP/serial/external pendingspeed
ser_data    No equivalent in ILOM
ser_parity  /SP/serial/external pendingparity
ser_stopbits    /SP/serial/external pendingstopbits
sys_autorestart /SP autorestart
sys_autorunonerror  /SP autorunonerror
sys_eventlevel  No equivalent in ILOM
sys_enetaddr    /HOST macaddress

Procedure to set the Serial Number after PDB replacement:

sc> setsc sc_servicemode true
Warning: misuse of this mode may invalidate your warranty.
sc> setcsn -c chassis_serial_number
Are you sure you want to permanently set the Chassis Serial Number
to chassis_serial_number[y/n]? y
Chassis serial number recorded.
sc> showplatform
SUNW,Sun-Fire-T5120
Chassis Serial Number: chassis-serial-number
Domain Status
------ ------
S0 Running
sc>setsc sc_servicemode false

HOW TO RESET ILOM PASSWORD:
InfoDoc #: 209731

Power down the host system (using the front panel powerbutton)
or if an SP admin account exists, you can alternatiely use that
accounts ALOM Command Line Interface poweroff command.

Unplug the system's power cord(s) Remove the system's top cover.

 Insert a Jumper (you provide the jumper) on Pins 1 & 2 of PJ6801.
 This Jumper is located at the T5120/T5220 Motherboard

 Insert a Jumper (you provide the jumper) on Pins 1 & 2 of J10401
 This Jumper is located on the SP of the T5140/T5240

- near the edge of the Motherboard at rear of the system -
  center of the rear edge of the Motherboard.

Plug in the system's power cord(s).

Press the front panel Power button to power on the system.
  You must power on the system to complete the reset.

This is because the state of the PJ6801 jumper cannot be
determined without the host CPU running.

The SP root password will be reset to the default  changeme.

Log in as root into the SP, using any available method - ssh
or a Web Browser to the SP's network management port or via
tip-hardware or a terminal server to the SP's serial management
port.

Password to use  is   changeme.

That is simply to see if the changeme password works.

Power down the system using the front panel

Unplug the system's power cord(s)

Remove the PJ6801 jumper. You must remove the PJ6801 jumper
after resetting the password, or the password will be reset
every time the SP is reset (e.g. at power up).

Replace the system's top cover.

Plug in the system's power cord(s).

If the system administrator would like the SP's root account
password changed to something other than  changeme  Then you
can change the root password using the usualSP's  root account's
Command Line User Interface command. Whether or not the SP's root
account password is to be changed to something different than changeme
after the top cover has been reinstalled and the system's power cord(s)
plugged-in, if the system administrator would like the Host powered-up,
that can be done using the front panel power button or via a login to
the SP's root or admin accounts and the appropriate START or
power on, respectively, may be used.